Metadata-Version: 2.4
Name: mtecconnect3dcp
Version: 2.0.1
Summary: OPC-UA client classes for m-tec machines (Mixingpump, Printhead, Dosingpump)
Home-page: https://github.com/m-tec-com/mtecConnect3DCP
Author: Paul Richter
Author-email: paul.richter@m-tec.com
Project-URL: Source, https://github.com/m-tec-com/mtecConnect3DCP
Project-URL: Tracker, https://github.com/m-tec-com/mtecConnect3DCP/issues
Keywords: opcua m-tec automation mixingpump pump printhead dosingpump duo-mix flow-matic smp p20 p50
Classifier: Programming Language :: Python :: 3
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Requires-Python: >=3.7
Description-Content-Type: text/markdown
Requires-Dist: asyncua>=1.0.0
Requires-Dist: pyserial>=3.5
Dynamic: author
Dynamic: author-email
Dynamic: classifier
Dynamic: description
Dynamic: description-content-type
Dynamic: home-page
Dynamic: keywords
Dynamic: project-url
Dynamic: requires-dist
Dynamic: requires-python
Dynamic: summary

# mtecconnect3dcp Python Library

This library provides a simple interface to connect and control m-tec machines via OPC UA and Modbus. It supports different machine types such as Mixingpump (duo-mix 3DCP (+), SMP 3DCP), Printhead (flow-matic PX), Dosingpump (flow-matic) via OPC-UA, and Pumps (P20, P50) via Modbus.

## Developer Friendliness & IDE Support

This library uses comprehensive Python docstrings and type annotations. As a result, modern IDEs such as Visual Studio Code provide automatic tooltips, autocompletion, and inline help (IntelliSense). This gives you immediate guidance on parameters, return values, and usage of functions and classes while coding.

**Note:** For the best experience, it is recommended to use VS Code or another IDE with Python IntelliSense support.

## Installation


1. Install this library:

```
pip install mtecconnect3dcp
```


### Example
See `/Python/example.py` for a full example. Below is a minimal usage guide:

```python
from mtecconnect3dcp import Printhead, Dosingpump, Pump, Duomix, DuomixPlus, Smp

# Connect to a Mixingpump
mp = Duomix()
mp.connect("opc.tcp://<MIXINGPUMP_IP>:4840")
mp.speed = 50  # Set speed to 50Hz (20-50Hz range)
mp.run = True  # Start the mixingpump

# Connect to a Printhead
ph = Printhead()
ph.connect("opc.tcp://<FLOW-MATIC_IP>:4840")
ph.speed = 1000  # Set speed to 1000 1/min
ph.run = True  # Start the printhead

# Connect to a Dosingpump
dp = Dosingpump()
dp.connect("opc.tcp://<FLOW-MATIC_IP>:4840")
dp.speed = 30  # Set speed to 30 ml/min
dp.run = True  # Start the dosingpump

# Connect to a Pump (P20/P50 via Modbus)
pump = Pump()
pump.connect(port="COM7")
pump.speed = 25  # Set speed to 25Hz
pump.run = True  # Start the pump
```

## Supported Properties and Functions by Machine

### Control

| Function/Property         | Get | Set | Type         | Description                        | Pump (P20 & P50)| duo-mix 3DCP | duo-mix 3DCP+ | SMP 3DCP | Dosingpump (flow-matic PX) | Printhead (flow-matic PX) |
|--------------------------|-----|-----|--------------|------------------------------------|------|---------|----------|-----|------------|-----------|
| run                      |  :white_check_mark:  |  :white_check_mark:  | bool         | Start/stop machine                 |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| reverse                  |  :white_check_mark:  |  :white_check_mark:  | bool         | Set/Get running reverse   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |  :x:   |  :x:   |
| emergcency_stop() |  :white_check_mark:  |  :x:  | function         | Execute Emergency Stop   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |  :x:   |  :x:   |
| speed                    |  :white_check_mark:  |  :white_check_mark:  | float/int    | Set/Get speed                      |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| dosingpump               |  :white_check_mark:  |  :white_check_mark:  | bool         | Start/stop dosingpump              |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| dosingspeed              |  :white_check_mark:  |  :white_check_mark:  | float        | Set dosingpump speed               |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| water                    |  :white_check_mark:  |  :white_check_mark:  | float        | Set water flow (l/h)               |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| cleaning                 |  :white_check_mark:  |  :white_check_mark:  | bool         | Start/stop cleaning water          |  :x:   |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |
| setDigital(pin, value)   |  :x:  |  :white_check_mark:  | function     | Set digital output                 |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| setAnalog(pin, value)    |  :x:  |  :white_check_mark:  | function     | Set analog output                  |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |

### Measure (GET)

| Function/Property        | Type         | Description        | Unit      | Pump (P20 & P50)| duo-mix 3DCP | duo-mix 3DCP+ | SMP 3DCP | Dosingpump (flow-matic PX) | Printhead (flow-matic PX) |
|--------------------------|--------------|--------------------|-----------|-----------------|--------------|---------------|----------|----------------------------|---------------------------|
| m_speed               | float        | speed              |           |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| m_dosingspeed         | float        | speed of dosing pump | %       |  :x:   |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |
| m_pressure            | float        | pressure           | bar       |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :white_check_mark: (optional)   |
| m_water               | float        | water flow         | l/h       |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| m_water_temperature   | float        | water temperature  | °C        |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| m_temperature         | float        | mortar temperature | °C        |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| m_valve               | float        | valve position     | %         |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| m_silolevel           | float        | Silo level         | %         |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |
| m_voltage             | bool         | Voltage            |           |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |  :x:   |  :x:   |
| m_current             | bool         | Current            |           |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |  :x:   |  :x:   |
| m_torque              | bool         | Torque             |           |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |  :x:   |  :x:   |
| getDigital(pin)       | function     | Digital input      | bool      |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| getAnalog(pin)        | function     | Analog input       | 0 - 65535 |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |



### Status (GET)

| Function/Property        | Type         | Description                        | Pump (P20 & P50)| duo-mix 3DCP | duo-mix 3DCP+ | SMP 3DCP | Dosingpump (flow-matic PX) | Printhead (flow-matic PX) |
|--------------------------|--------------|------------------------------------|------|---------|----------|-----|------------|-----------|
| s_error                    | bool | error state                    |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| s_error_no                 | int  | error number                   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| s_ready                    | bool | Ready for operation            |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| s_mixing                   | bool | mixing                         |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_pumping                  | bool | pumping                        |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_pumping_net              | bool | pumping via net                |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_pumping_fc               | bool | pumping via FC                 |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_remote                   | bool | hardware remote connected      |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |
| s_solenoidvalve            | bool | solenoid valve open            |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_waterpump                | bool | pumping waterpump running      |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_emergency_stop           | bool | emergency stop ok              |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |
| s_on                       | bool | machine powered on             |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |
| s_safety_mp                | bool | mixingpump safety ok           |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_safety_mixer             | bool | mixer safety ok                |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_circuitbreaker_fc        | bool | Frequency Converter circuit breaker ok |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_circuitbreaker           | bool | other circuit breaker ok       |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_fc                       | bool | frequency converter ok         |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |
| s_operating_pressure       | bool | pressure ok                    |  :x:   |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |
| s_water_pressure           | bool | water pressure ok              |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_hopper_wet               | bool | wet material hopper ok         |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_hopper_dry               | bool | dry material hopper ok         |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_running_local            | bool | running in local mode          |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_phase_reversed           | bool | phase reversed                 |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_running                  | bool | Mixingpump running forward     |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :white_check_mark:   |
| s_running_reverse          | bool | Mixingpump running reverse     |  :white_check_mark:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |  :x:   |
| s_rotaryvalve              | bool | rotary valve running           |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_compressor               | bool | compressor running             |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_vibrator_1               | bool | vibrator 1 running             |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |
| s_vibrator_2               | bool | vibrator 2 running             |  :x:   |  :x:   |  :x:   |  :white_check_mark:   |  :x:   |  :x:   |

### Subscriptions

| Description                        | Pump (P20 & P50)| duo-mix 3DCP | duo-mix 3DCP+ | SMP 3DCP | Dosingpump (flow-matic PX) | Printhead (flow-matic PX) |
|------------------------------------|------|---------|----------|-----|------------|-----------|
| Subscribe to variable changes      |  :x:   |  :white_check_mark:   |  :white_check_mark:   |  :white_check_mark:   |  :x:   |  :x:   |

You can subscribe to OPC UA variables for real-time updates:

```python
def callback(value, parameter): # value and parameter (origial OPC-UA variable name) are optional
    print(f"{parameter} changed to {value}")
mp = Duomix()
mp.s_ready = callback # set a variable to you callback to subscribe
```
---